A Look at most of the 19,790 units sleeves (Seal Ring, P. № - BCA 500), used by OMS in the manufacture of BCD in the period from May 11, 2006 on August 1, 2007, have a latent defect.
On the net 'is the possible collapse of bushings, which could result in a leak in the compensator, which in turn can lead to loss of buoyancy control and endanger the life of a diver.
P Producers warns all divers who use buoyancy compensators with the serial numbers given in the table below, immediately discontinue use of compensators and immediately contact the nearest service center OMS and give your compensator (wing) to carry out checks on the latent defect.
If the service center is not available in your country please contact your nearest distributor or dealer OMS . Examination and replacement of defective parts of the compensator will be made free of charge.
Serial number
06053339 ~ 06053388
06054948 ~ 06054997
06054998 ~ 06055047
06054848 ~ 06054897
06054898 ~ 06054947
06054723 ~ 06054797
06054798 ~ 06054847
06054519 ~ 06054618
06054369 ~ 06054518
06068461 ~ 06068510
06062400 ~ 06062449
06067933 ~ 06067982
06062920 ~ 06062969
06068083 ~ 06068107
06067983 ~ 06068032
06068033 ~ 06068057
06068058 ~ 06068082
06062820 ~ 06062869
06062350 ~ 06062399
06062770 ~ 06062819
06062300 ~ 06062349
06097048 ~ 06097247
06096847 ~ 06097046
06097247 ~ 06097446
06097597 ~ 06097746
Serial number
06097447 ~ 06097596
06097747 ~ 06097946
06092110 ~ 06092209
06091830 ~ 06091904
06091905 ~ 06091979
06101980 ~ 06102029
06102030 ~ 06102059
06102060 ~ 06102109
07049286 ~ 07049315
07049316 ~ 07049390
07049206 ~ 07049235
07049176 ~ 07049205
07049236 ~ 07049285
07042526 ~ 07042625
07042496 ~ 07042525
07042626 ~ 07042700
07042776 ~ 07042850
07042701 ~ 07042775
07056023 ~ 07056062
07066063 ~ 07066162
07066263 ~ 07066362
07066632 ~ 07066706
07066163 ~ 07066212
07066213 ~ 07066262
07066707 ~ 07066806
Serial number
07066532 ~ 07066631
07066363 ~ 07066462
07066807 ~ 07066881
07066467 ~ 07066531
07066882 ~ 07066896
07079216 ~ 07079365
07076116 ~ 07076215
07086066 ~ 07086115
07070481 ~ 07070483
07070492 ~ 07070501
07070506 ~ 07070520
07076472 ~ 07076543
07070793 ~ 07070892
07020016 ~ 07020065
07066023 ~ 07066062
07060293 ~ 07060492
07089466 ~ 07089615
07070168 ~ 07070242
07089816 ~ 07089965
07086130 ~ 07086179
07089616 ~ 07089765
07080243 ~ 07080292
07079366 ~ 07079465
07080068 ~ 07080617
By ML, indicating the production date of your compensator can be read as follows: 0805XXXX code contains the year (08 = 2008), month (05 = May) and the number of products (the last 4 digits). For example: 05080001, 05080002, etc.
Dr. Iver from Russia may apply to an authorized service center OMS tel. +7 (495) 956-20-21, regardless of place of purchase compensator.
In the Arab Republic of Egypt authorized dealers OMS now unfortunately no.
Tusa recalls faulty controllers A major international manufacturer and distributor of equipment and accessories for diving TUSA, announced the withdrawal of the Party controls RS-670 sold from May to September 2009 ...
Apeks WTX recall compensators A well-known producer of dive gear Aqua Lung, who owns the trademark Apeks, said the withdrawal of compensators WTX due to a problem with the button blowing inflator. According ...
Poseidon recalls defective wings Besea W50 A well-known manufacturer of equipment for diving - a Swedish company, Poseidon, reports the withdrawal of defective wing model Besea W50. After 15 cases of rupture of internal chambers ...
SI TECH withdraws faulty hoses with flow controller The Swedish manufacturer of dry suits, accessories and other dive gear SI TECH reports of withdrawal of low pressure hoses, manufactured and sold in ...
Care equipment Step by step guide on caring for divers' equipment before and after immersion. If you are seriously keen on diving, you probably have invested a lot of money ...